{"id":33592,"date":"2026-09-16T06:59:41","date_gmt":"2026-09-16T06:59:41","guid":{"rendered":"https:\/\/fenchenergy.com\/?post_type=product&#038;p=33592"},"modified":"2026-10-26T01:21:30","modified_gmt":"2026-10-26T01:21:30","slug":"disjoncteur-dc-220a-mccb-boite-de-batterie-diy","status":"publish","type":"product","link":"https:\/\/fenchenergy.com\/fr\/product\/220a-dc-circuit-breaker-mccb-diy-battery-box\/","title":{"rendered":"Disjoncteur DC MCCB 220A pour bo\u00eetes \u00e0 batteries DIY | Isolateur de batterie 2 p\u00f4les, stock UE"},"content":{"rendered":"<div data-elementor-type=\"product-post\" data-elementor-id=\"33592\" class=\"elementor elementor-33592\" data-elementor-post-type=\"product\">\n\t\t\t\t<div class=\"wd-negative-gap elementor-element elementor-element-1288afa0 e-flex e-con-boxed e-con e-parent\" data-id=\"1288afa0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-77349a6e elementor-widget__width-initial color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"77349a6e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>Un disjoncteur DC 220A fait une chose que votre BMS ne peut pas faire seul : il vous offre une coupure physique dans le circuit.<\/strong> Votre BMS prot\u00e8ge les cellules contre les surintensit\u00e9s et les courts-circuits, mais lorsque vous devez travailler sur le pack, isoler l'onduleur ou couper l'alimentation en cas d'urgence, vous avez besoin de quelque chose que vous pouvez r\u00e9ellement \u00e9teindre. Ce disjoncteur DC 2 p\u00f4les se place entre votre batterie et votre onduleur, ajoute une protection contre les courts-circuits en plus du BMS, et vous donne un point de d\u00e9connexion visible.<\/p><h3>Pourquoi un disjoncteur DC 220A est pr\u00e9f\u00e9rable \u00e0 se fier uniquement au BMS<\/h3><p>Un BMS est un dispositif de protection, pas un interrupteur. Il coupe le courant lorsqu'il y a un probl\u00e8me, mais il ne vous permet pas d'isoler le pack \u00e0 la demande \u2014 et il ne peut pas \u00e9liminer un court-circuit franc sur l'alimentation DC principale comme le fait un disjoncteur. Ajouter un disjoncteur vous offre trois choses qu'un BMS seul ne peut pas :<\/p><ul><li><strong>Une d\u00e9connexion manuelle<\/strong> pour la maintenance, les mises \u00e0 niveau et les urgences<\/li><li><strong>\u00c9limination des courts-circuits<\/strong> class\u00e9e \u00e0 7,5kA<\/li><li><strong>Un d\u00e9faut visible<\/strong> \u2014 un disjoncteur d\u00e9clench\u00e9 vous montre qu'il s'est pass\u00e9 quelque chose, au lieu de vous laisser deviner<\/li><\/ul><h4>Les disjoncteurs AC n'ont pas leur place sur un circuit de batterie<\/h4><p>C'est l'erreur la plus importante. Le courant alternatif passe par z\u00e9ro 50 \u00e0 60 fois par seconde, et ce passage par z\u00e9ro permet au disjoncteur AC d'\u00e9teindre l'arc lorsqu'il d\u00e9clenche. Le courant continu n'a pas de passage par z\u00e9ro, donc l'arc continue de br\u00fbler. Un disjoncteur AC peut ne pas r\u00e9ussir \u00e0 \u00e9liminer un d\u00e9faut sur un syst\u00e8me de batterie, ce qui est pr\u00e9cis\u00e9ment la situation qu'un disjoncteur est cens\u00e9 r\u00e9soudre.<\/p><h3>Ce que signifie la capacit\u00e9 220A en pratique<\/h3><p>La configuration la plus courante dans un pack de stockage DIY est un BMS 200A. Ce disjoncteur est class\u00e9 \u00e0 220A, un cran au-dessus, ce qui vous donne une marge pour le courant d'appel sans surdimensionner l'appareil ou le c\u00e2ble.<\/p><div><div><table><thead><tr><th>Votre BMS<\/th><th>Disjoncteur \u00e0 choisir<\/th><\/tr><\/thead><tbody><tr><td>200A \u2014 la configuration DIY standard<\/td><td><strong>220A (ce mod\u00e8le \u2014 BCPS2DM220)<\/strong><\/td><\/tr><tr><td>Packs plus grands n\u00e9cessitant plus de marge<\/td><td>250A (BCPS2DM250)<\/td><\/tr><tr><td>BMS 300A et syst\u00e8mes \u00e0 haute puissance<\/td><td>300A (BCPS2DM300)<\/td><\/tr><\/tbody><\/table><\/div><\/div><p>Une r\u00e8gle plus importante que le tableau : ne jamais installer un disjoncteur dont la capacit\u00e9 nominale est inf\u00e9rieure au courant continu de votre syst\u00e8me, et ne jamais installer un c\u00e2ble dont la capacit\u00e9 est inf\u00e9rieure \u00e0 celle du disjoncteur.<\/p><h3>Lire l'\u00e9tiquette : capacit\u00e9 nominale DC et capacit\u00e9 de coupure<\/h3><div><div><table><thead><tr><th>Marking<\/th><th>What it means<\/th><\/tr><\/thead><tbody><tr><td><strong>125\/250V DC<\/strong><\/td><td>DC voltage rating \u2014 125V per pole, 250V with both poles<\/td><\/tr><tr><td><strong>2P<\/strong><\/td><td>Two poles, breaking together<\/td><\/tr><tr><td><strong>220A<\/strong><\/td><td>Rated continuous current<\/td><\/tr><tr><td><strong>Icu\/Ics 7.5kA<\/strong><\/td><td>Short-circuit breaking capacity<\/td><\/tr><tr><td><strong>IEC 60947-2<\/strong><\/td><td>The switchgear standard the device is marked to<\/td><\/tr><\/tbody><\/table><\/div><\/div><h3>Fitting a DC Circuit Breaker Into a DIY Battery Box<\/h3><p>At 78 \u00d7 38 \u00d7 63mm and 225g, this breaker fits inside a battery enclosure or a tight cabinet instead of needing its own panel.<\/p><ol start=\"1\"><li><strong>Mount it where you can reach it.<\/strong> A breaker you cannot access is decoration.<\/li><li><strong>Follow the LINE and LOAD markings<\/strong>, and confirm the wiring diagram in the manual before connecting.<\/li><li><strong>Torque the terminals to spec<\/strong> and re-check after the first thermal cycle.<\/li><li><strong>Keep AC and DC separate.<\/strong> This device goes on the DC side between battery and inverter.<\/li><li><strong>Leave room for the cables.<\/strong> Thick DC cable needs bend radius.<\/li><\/ol><h3>Sp\u00e9cifications<\/h3><div><div><table><thead><tr><th>Param\u00e8tre<\/th><th>Sp\u00e9cification<\/th><\/tr><\/thead><tbody><tr><td>Model<\/td><td>BCPS2DM220<\/td><\/tr><tr><td>Type<\/td><td>2-pole DC circuit breaker (MCCB)<\/td><\/tr><tr><td>Rated current<\/td><td>220A<\/td><\/tr><tr><td>Voltage rating<\/td><td>125\/250V DC<\/td><\/tr><tr><td>Breaking capacity<\/td><td>Icu\/Ics 7.5kA<\/td><\/tr><tr><td>Dimensions<\/td><td>78 \u00d7 38 \u00d7 63mm<\/td><\/tr><tr><td>Poids<\/td><td>225g<\/td><\/tr><tr><td>Application<\/td><td>Short-circuit protection and manual isolation for battery boxes<\/td><\/tr><tr><td>Standard marking<\/td><td>IEC 60947-2<\/td><\/tr><tr><td>Shipping<\/td><td>EU stock, DDP delivery from Poland<\/td><\/tr><\/tbody><\/table><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>\ud83d\udd0c Disjoncteur DC 220A MCCB \u2014 Isolateur de batterie 2 p\u00f4les<br \/>\n\u2705 Disjoncteur 2 p\u00f4les DC pour bo\u00eetes de batterie DIY | 125\/250V DC<br \/>\n\u26a1 220A nominal | Capacit\u00e9 de coupure de court-circuit Icu\/Ics 7,5kA<br \/>\n\ud83d\udd17 Compatible avec les montages BMS 200A \u2014 JK V19 200A et similaires<br \/>\n\ud83d\udcd0 Compact 78 \u00d7 38 \u00d7 63mm | 225g | s'installe \u00e0 l'int\u00e9rieur du bo\u00eetier<br \/>\n\u26a0\ufe0f Disjoncteur uniquement \u2014 bo\u00eete, BMS et cellules NON inclus<br \/>\n\ud83d\ude9a Stock UE | Entrep\u00f4t en Pologne<\/p>","protected":false},"featured_media":33593,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[305],"product_tag":[],"class_list":["post-33592","product","type-product","status-publish","has-post-thumbnail","product_cat-accessories-parts","first","instock","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/fenchenergy.com\/fr\/wp-json\/wp\/v2\/product\/33592","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fenchenergy.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/fenchenergy.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/fenchenergy.com\/fr\/wp-json\/wp\/v2\/comments?post=33592"}],"version-history":[{"count":1,"href":"https:\/\/fenchenergy.com\/fr\/wp-json\/wp\/v2\/product\/33592\/revisions"}],"predecessor-version":[{"id":34240,"href":"https:\/\/fenchenergy.com\/fr\/wp-json\/wp\/v2\/product\/33592\/revisions\/34240"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/fenchenergy.com\/fr\/wp-json\/wp\/v2\/media\/33593"}],"wp:attachment":[{"href":"https:\/\/fenchenergy.com\/fr\/wp-json\/wp\/v2\/media?parent=33592"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/fenchenergy.com\/fr\/wp-json\/wp\/v2\/product_brand?post=33592"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/fenchenergy.com\/fr\/wp-json\/wp\/v2\/product_cat?post=33592"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/fenchenergy.com\/fr\/wp-json\/wp\/v2\/product_tag?post=33592"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}